The VE.Direct port can be connected to:
Battery voltage, AC output voltage, charge indicator, alarms
The full-bridge topology with a toroidal transformer has proven its reliability over many years.
The inverters are protected against short circuit and overheating, whether due to overload or high ambient temperature.
Needed to start up high loads, such as inverter loads for LED bulbs, incandescent bulbs or power tools.
In ECO mode, the inverter switches to standby (all outputs off) when no power is detected for a set period.
It then switches on again every X seconds (adjustable) to check if the load has increased.
A remote On/Off switch can be connected to a two-pole connector, or between the positive pole of the battery and the left contact of the two-pole connector.
A red and green LED indicate the status of the inverter and the status of the various protections.