LiFePO4 battery: it prevents undervoltage, overvoltage and overheating of the cells
The first line of protection is cell balancing. All Victron LiFePO4 batteries incorporate cell balancing.
The second line of protection consists of:
- shutting down the load in case of imminent undervoltage on the cells, and
- stopping and reducing the charging current in case of imminent overvoltage on the cells, high temperature (>50°C) or low temperature (<0°C).
The VE.Bus BMS is the heart of the second line of protection.
However, not all loads or chargers can be controlled directly by the VE.Bus BMS
In order to shut down these loads or chargers, several Cyrix switches controllable by the VE.bus BMS are available
Cyrix-Li-load
The Cyrix-Li-load will deactivate when its control input becomes floating.
If the battery voltage recovers after disconnection (which will happen when no other load is connected to the battery), the BMS output will rise and the Cyrix will reactivate after 30 seconds. After 3 reactivation attempts, the Cyrix will remain deactivated until the battery voltage is above 13V (26 or 52V resp.) for at least 30 seconds (which means the battery is being charged).
Alternatively, a Protect battery can be used (advantage: very low power consumption).
LED status indication
- LED on: active = relay closed
- LED off, blinking every 10 s: inactive = relay open
- LED blinking every 2s: relay open; will close